Oxygen central station
Automatic Oxygen Station
An Automatic Oxygen Manifold Station is an essential component of medical gas systems in hospitals and healthcare facilities. It provides a practical and reliable solution for managing the supply of medical oxygen from oxygen cylinders to the hospital’s central medical gas pipeline system.
The Automatic Oxygen Station is designed to automatically control the changeover between two oxygen cylinder banks, helping maintain a continuous oxygen supply and reducing the need for manual intervention when one cylinder bank becomes depleted.
The station has a capacity of up to 140 cubic meters per hour (140 m³/h) and is equipped with Japanese components with local assembly, in addition to flexible hoses for connecting the oxygen cylinders.
What Is an Automatic Oxygen Manifold Station?
An Automatic Oxygen station , also known as an Automatic Oxygen Station, is a centralized control unit used to connect groups of oxygen cylinders to a medical gas pipeline system.
The manifold regulates the supply of oxygen from two cylinder banks and automatically changes over from one bank to the other when required, helping maintain a continuous oxygen supply to the medical gas network.
Components of the Automatic Oxygen Manifold Station
The station consists of an integrated system designed to manage the medical oxygen supply. Its main components include:
Automatic Changeover Between Two Oxygen Banks
The station features an automatic changeover system between two oxygen banks. Each bank can be connected to 5 oxygen cylinders.
This configuration allows the system to automatically switch between the two cylinder banks when required, helping maintain the oxygen supply to the medical gas pipeline.
Five Oxygen Cylinders per Bank
Each of the two oxygen banks is designed to connect to 5 oxygen cylinders, allowing a total of 10 oxygen cylinders to be connected to the station.
This configuration provides a practical oxygen supply solution for healthcare projects that use oxygen cylinders as their medical oxygen source.
Capacity of 140 Cubic Meters per Hour
The Automatic Oxygen Manifold Station has a capacity of up to 140 cubic meters of oxygen per hour (140 m³/h).
This capacity makes the station suitable for various medical gas applications requiring an appropriate oxygen flow rate. The required capacity should be determined according to the facility’s oxygen consumption, size, and medical gas pipeline design.
Flexible Hoses for Oxygen Cylinder Connection
The station is equipped with flexible hoses for connecting oxygen cylinders, making it easier to connect and organize the cylinders within the medical gas supply area.
The flexible hoses provide a practical solution for connecting and disconnecting oxygen cylinders during cylinder replacement, operation, and maintenance.

Features of the Automatic Oxygen Manifold Station
The Automatic Oxygen Station offers several important features for medical gas systems, including:
- Automatic changeover between two oxygen cylinder banks.
- Two oxygen banks, each connected to 5 cylinders.
- Capacity to connect a total of 10 oxygen cylinders.
- Oxygen supply capacity of up to 140 m³/h.
- Flexible hoses for connecting oxygen cylinders.
- Japanese components.
- Local assembly.
- Suitable for medical oxygen and medical gas pipeline systems.
Importance of an Automatic Oxygen Manifold in Hospitals
Hospitals require a continuous and reliable medical oxygen supply to meet the needs of different departments. Therefore, the oxygen manifold is an important part of the medical gas infrastructure.
The automatic changeover system between the two cylinder banks helps reduce the need for manual switching and allows the medical gas network to continue receiving oxygen from the available cylinder bank according to the system’s operating condition.
This feature is particularly important for healthcare facilities that require a continuous oxygen supply around the clock.
Applications of the Automatic Oxygen Manifold Station
The Automatic Oxygen Manifold Station can be used as part of medical gas systems in various healthcare facilities, including:
- Hospitals.
- Medical centers.
- Intensive Care Units (ICUs).
- Operating rooms.
- Emergency departments.
- Healthcare facilities.
- Medical facilities that use oxygen cylinders as a source of medical oxygen.
High-Quality Automatic Oxygen Manifold Station
When selecting an Automatic Oxygen Manifold Station for a hospital, it is important to consider the station’s capacity, the number of cylinders it can accommodate, the automatic changeover system, the quality of its components, and its compatibility with the medical gas pipeline system.
This Automatic Oxygen Manifold provides a practical solution for managing the supply of medical oxygen from oxygen cylinders to the central medical gas network, with an automatic changeover system between two oxygen cylinder banks.
Elsafa Trade – Medical Gas Systems
Elsafa Trade provides medical equipment and solutions for hospitals and healthcare facilities, including medical gas and central oxygen systems.
The Automatic Oxygen Manifold Station is a suitable solution for projects that require a centralized oxygen supply management system using oxygen cylinders, with the ability to connect up to 10 cylinders through two cylinder banks and automatically control the changeover between them.
For more information about the Automatic Oxygen Manifold Station and the appropriate specifications for your project, contact Elsafa Trade to determine the suitable solution based on the facility’s requirements and medical gas system design.
Related Products
-
Medical compressed air station
Medical Compressed Air Station A Medical Compressed Air Station is one of the essential components of a hospital medical gas system. It provides a continuous and reliable source of compressed medical air for various healthcare applications, particularly in operating rooms, intensive care units, emergency departments, and…








Reviews
There are no reviews yet.